“This detailed reporting tool became an important component of our inspection efforts and provided us with valuable historical data,” a representative of a large U.S. gas grid operating company said. “The leak data was shared with our integrity management group. The right-of-way (ROW) video was enormously important to our encroachment control department.”
The laser light is reflected back to the unit and the system uses the scattered signal to determine how much of the laser energy was absorbed. A complex algorithm calculates the total methane content along the laser light path from the helicopter to the background. This concept has worked at flight levels of about 500 feet.
The narrow spectral range helps avoid false readings from other gases so only methane is indicated. Leaks above a certain level trigger an alarm in real time and the grid operator on the ground is notified immediately. Data can be post-processed to categorize the findings and generate reports specifically tailored to the needs of the operator.Principle of operation of the Laser Gas Leak Detector
- The principle of ALMA is based on a pulsed beam from a diode laser, which is pointed at the location to be inspected.
- The laser wavelength of 1,65 μm corresponds to the fi rst absorption band of methane.
- The laser beam aimed downwind of the pipeline, is refl ected and the scattered refl ection is collected by a receiving mirror.
- A photo-detector receives the signal which is compared to the signal from a reference channel. (A laser beam through a curette with a standardized methane sample.)
- When methane is present the laser light will be absorbed, and the deformation of the signal is proportional to the concentration of methane along the laser beam path.
This technology is used mainly for transmission, distribution and gathering lines. It is also adaptable for special applications such as pressure tests or landfill monitoring. In the first phase the operator often specifies the scope of the inspection and provides the three-dimensional shape files when available.
The operator sets the best time for the inspection – excluding the times of the year with extreme temperatures and severe weather conditions – and decides if an inspector aboard the helicopter will complete the classic visual inspection concurrently with data capturing.
With the addition of the shape files the inspection and flight planning can begin. Carefully planned inspections save ferry flights for refueling. Depending on the availability of the helicopter, the crew and weather conditions, the inspection can be performed autonomously.
The report with the flown track, the gas concentration values over the pipeline, a record of leaks along with their precise location and a complete video documentation of the ROW are provided within a couple days of the inspection. The inspection includes a follow-up meeting to discuss the data and determine the inspection cycle. If there are no major incidents, this type of patrol is typically completed every six to 12 months.
The ALMA gas leak detection system was developed in 2002 in Switzerland for Gazprom, Russia’s largest natural gas transportation company, to locate leaks and simultaneously detect security threats.“The technology itself is proven; now we are designing certified mounts for a variety of helicopters and streamlining the production process.” said Peter Mantel, managing director of manufacturer Pergam.
In the interim, the third generation of the system is commercially available and used in more than 24 countries. The main benefit of this technology is safety during the inspection for the crew and for the pipeline. This method also offers independence from most weather conditions. Limitations of this technology are mainly related to flight restrictions in densely populated areas. In these cases, the same laser technology is available to mount on ground vehicles.The advantages of ALMA are numerous:
- Airborne device mounted on a helicopter
- Highly sensitive, wide measurement range
- Real time measurement and alarm feature
- Insensitive to other gases (water vapor, propane)
- Minimal interference with environment
- Pilot camera and monitor to aim laser
- Digital video recording with up to 4 cameras to document laser position and area
- around pipeline
- Extensive data storage capacity
- GPS tracking utilising map system navigation
- Laser Range Finder
- Post processing software
- Optional IR camera installation